Premium Photometric Accuracy & Stray Light Calibration Reference Standards Kit 1
These Reference Standards correspond or exceed requirements of NIST930e established by NIST National Institute of Standards & Technology, USA.
Our unique materiaI-formation and nano-deposition proprietary manufacturing process assures unmatched stability of optical performance of WAV-7 Calibration Standard. WAV-7 NEVER needs to be recalibrated due to materiaI aging.
Benefits of using Solid Based Calibration Reference Standards:
- Highly accurate and consistent spectrophotometer calibration every time
- Never have to be replaced, one kit will last forever
- Save recalibration time, these calibration standards never have to be recalibrated due to material aging
- Easy to handle due to scratch resistant coating
- Can be used in any UV VIS spectrophotometer
- Standard 12.5 x 12.5 mm dimensions
- Meets or exceeds all the requirements of NIST930e standard
- NIST Compatible
This UV/VIS calibration kit can test the following:
- Photometric Accuracy - In the UV and VIS range
- Stray Light Performance of Spectrophotometers- in the UV and VIS range
NIST Traceable data tables/charts are available for qualified customers.
Liquid and Solid-State Neutral Density filters for testing photometric accuracy of spectrophotometers are typically calibrated by the filters' manufacturers, and the corresponding filters performance certificates are supplied to customers. Whereas solid-state filters typically maintain their performance for many years, performance of liquid filters degrades much quicker due to so-called slow irreversible chemical reactions, photonic-promoted chemical reactions, and certain other reasons.Therefore, manufacturers of liquid filters typically request customers to replace liquid filters every 1 to 3 years.
At the same time, until recently solid-state neutral density filters had substantial non-linearity across their surface which caused substantial contribution to so-called "Expanded Uncertainty"*. This was a disadvantage of solid-state neutral density filters.
*As defined by NIST.
Modern development of nano-technology allowed us to develop state-of art solid-state quantum resonance filters towards replacing liquid filters, such that customers can benefit from substantial savings on filters' replacements.
The optical wavelength range of operations of our FUV-1 Stray Light/Photometric Accuracy Filter is 200-700 nm and 400-700 nm for the other neutral density filters included in this kit.
Photometric data tables are available for qualified customers. Please contact us for more information.
The instruction on how to use this kit is included with the every sold product.
| This kit includes: | |
| 1 Neutral Density Filter | H-F2-0.25 |
| 1 Neutral Density Filter | H-F3-0.5 |
| 1 Neutral Density Filter | H-F4-1 |
| 1 Stray Light Filter | FUV-1 |
| 1 Case | CaseP4 |